DescriptionTreat AltGr+Shift different from AltGr.
According to Indic users, there should be 4 shift levels of keyboard symbols:
(1) no modifier keys are held
(2) Shift key is pressed
(3) AltGr key is pressed
(4) both Shift and AltGr keys are pressed
Previously ibus-m17n only recognizes 1-3. This patch enables the 4th case.
BUG=none
TEST=manual
Patch Set 1 #
MessagesTotal messages: 2
|